6 Electrical connection
► Disconnect the plant from the mains supply before installation, if
necessary, also disconnect any independently supplied output load
circuits�
► Observe the national and international regulations for the installation of
electrical equipment�
► Observe the requirements according to IEC EN 60204�
Accessible surfaces of the device are insulated from the circuits with basic
insulation to IEC 61010-1 (secondary circuit with max� 32 V DC, supplied from
main circuit up to 300 V of overvoltage category II)�
The external wiring has to be carried out in a way that ensures the required
separation from other circuits�
6.1 Wiring
Wiring (→ 9 Technical data)
The connection terminals may only be supplied with the signals indicated in
the technical data / on the device label and only the approved accessories
from ifm electronic gmbh may be connected�
The device is designed for supply via a mobile on-board system (12/24 V
DC nominal voltage) or SELV/PELV according to the technical data and
national regulations� The supply is directly transferred to the connected
sensors/actuators without electrical separation�
6.2 General wiring information
The supply cables and the CAN2 interface are connected via the X1 connector
on the bottom of the device� The inputs/outputs, the CAN1 interface and the CAN
supply are connected via the M12 connectors on the front side of the housing�
Wiring (→ 9 Technical data)