5.3 Fixing
► Insert the enclosed tubular rivets from the back of the device in the 3 fixing
holes�
► Fix the device using 3 washers and M5 screws�
Tighten the screws alternately�
Use of the tubular rivets
Tightening torque: 2�0 Nm
Hole dimensions (→ 9 Technical data)
Screws to be used (examples): Standard
Cylinder screws with hexagon socket (M5 x L) DIN EN ISO 4762
Cylinder screws with hexagon socket and low head (M5 x L) DIN 7984
5.4 Cable seal
Before and during installation, observe the pollution degree
(→ 9 Technical data) until the protection rating is ensured by means of
connectors/dummy plugs� Protection rating IP 65 / IP 67 is only guaranteed
if all ports are sealed by means of connectors or dummy plugs�
The gap dimensions of the unit may vary�