IO-Link master with EtherNet/IP interface AL1327
99
Request channel
Byte
(offset)
Bit
7 6 5 4 3 2 1 0
4 Port No. (LSB)
5 Port No. (MSB)
6 Index (LSB)
7 Index (MSB)
8 Subindex (LSB)
9 Subindex (MSB)
10 Trigger Command ID
11 Data Length
12 Data (Byte 0)
13 Data (Byte 1)
… …
43 Data (Byte 31)
44 reserved
45 reserved
Legend:
• Port No. IO-Link Port
Port No. 0x1234
• Port No. (MSB): 0x12
• Port No. (LSB): 0x34
1WORD • 0x0001: Port 1
• 0x0002: Port 2
• 0x0003: Port 3
• 0x0004: Port 4
• 0x0005: Port 5
• 0x0006: Port 6
• 0x0007: Port 7
• 0x0008: Port 8
• Index Index of the ISDU object
Index: 0x1234
• Index (MSB): 0x12
• Index (LSB): 0x34
1WORD 0x0000…0xFFFF
• Subindex Subindex of the ISDU object
Subindex 0x1234
• Subindex (MSB): 0x12
• Subindex (LSB): 0x34
1WORD 0x0000…0xFFFF
• Trigger Control of the command execution 1BIT • 0x0: no action
• 0x1: Execute command
• Command ID Command number 7BIT • 0x01: Get
• 0x02: Write
• Data Length Number of bytes that contain relevant user
data
1BYTE • 0x00: 0 bytes
…
• 0x20: 32 bytes
• Data (byte n) User data (byte n) 1 BYTE Pro byte:
• 0x00…0xFF