63
init
running stopped
error
start / reset start stop / reset
stop
start
stopstart / reset
stop
reset
After successful initialisation in the [init] state, the connection automatically changes to the [running]
state.
The connection automatically assumes the [error] state if at least one of the following events occurs:
• no MQTT broker can be reached
Maximum number of MQTT broker: 1
Maximum number of simultaneous MQTT connections: 3
Substructure: connections/mqttConnection
Available data points:
Name Description Value range Access
../type Type of the connection (MQTT) mqtt: MQTT connection ro
1
../status Status of the MQTT connection • init: [init] state– initialisation
• stopped: [stopped] state–
connection stopped
• running: [running] state–
connection running
• error: [error] state
ro
1
../status/preset Presetting of the status of the MQTT
connection
• running: [running] state (default) ro
1
../MQTTSetup Substructure for general MQTT settings
../MQTTSetup/QoS Quality of Service (QoS) of the MQTT
connection
• 0: QoS level 0 - PUBLISH (without
confirmation) (default)
• 1: QoS level 1 - PUBLISH >
PUBREC (single confirmation)
• 2: QoS level 2 - PUBLISH >
PUBREC > PUBREL > PUBCOMP
(double confirmation)
rw
2
../MQTTSetup/version MQTT version e.g. 3.1.1 ro
1
1
Read only
2
Read and write
Applicable services:
Name Description
../status/start Activate MQTT.
../status/stop Deactivate MQTT.
../status/reset Reset MQTT.