IFB Neptune SX1 handleiding
Handleiding
Je bekijkt pagina 39 van 47

FAILURE CODES AND
WHAT TO DO IN CASE OF
FAILURE
36
ERROR CODE ERROR DESCRIPTION CONTROL
FF
Inadequate water supply
• Make sure the water input tap is totally open and that there is no water cut.
• Close the water input tap, separate the water input hose from the tap and clean the filter at
the connection end of the hose.
• Restart your machine, contact the service if the error resumes.
F3
Error of continuous water input
• Close the tap.
• Contact the service.
F2
The waste water in the machine cannot be
discharged.
• Water discharge hose is clogged.
• The filters of your machine might be clogged.
• Power off-on your machine and activate the program cancellation command.
• If the error continues, contact the service.
F8
Heater error
Contact the service.
F1
Alarm is active against water overflow
• Power off your machine and close the tap.
• Contact the service.
FE
Faulty electronic card Contact the service.
F7
Overheating error (temperature in the machine is
too high) Contact the service.
F9
Divisor position error Contact the service.
F6
Faulty heater sensor Contact the service.
F5
Circulation Pump or pressure switch can be broken
Contact the service.