Do not bend the drain hose or leave it
protruding or twisted and do not put
the end of it in water. If an extension is
connected to the drain hose, ensure
that it is lagged when it passes into the
indoor unit.
If the piping is installed to the right, the
pipes, power cable and drain hose
must be lagged and secured onto the
rear of the unit with a pipe connection.
Insert the pipe connection into the
relative slot.
Press to join the pipe connection to the
base.
Installation of the indoor unit
After having connected the pipe
according to the instructions, install the
connection cables.
Now install the drain pipe. After
connection, lag the pipe, cables and
drain pipe with the insulating material.
Arrange the pipes, cables and drain
hose well.
Lag the pipe joints with insulating
material, securing it with vinyl tape.
Run the bound pipe, cables and drain
pipe through the wall hole and mount
the indoor unit onto the upper part of
the mounting plate securely.
Press and push the lower part of the
indoor unit tightly against the
mounting plate.
Installation of the outdoor unit
Outdoor unit condensed water drainage
(only for heat pump models)
The condensed water and the ice formed
in the outdoor unit during heating
operation can be drained off through the
drain pipe
Fasten the drain port in the 25 mm hole
placed in the part of the outdoor unit.
Connect the drain port and the drain
pipe. Ensure that the water is drained in
a suitable place.
21
24