Final stage of installation
• Place wind insulating covering around
the joints of the indoor unit and fix it with
insulating tape.
• Fix the exceeding part of the signal
cable to the piping or to the outdoor
unit.
• Fix the piping to the wall (after having
coated it with insulating tape) using
clamps or insert them into plastic slots.
• Seal the hole in the wall through which
the piping is passed so that no air Or
water can fill.
Indoor unit test
• Do ON/OFF and fan operate normally?
• Do the various modes operate
normally?
• Does the Timer function properly?
• Does each LED function normally?
• Do the flaps for airflow direction
operate normally?
• Is the condensed water drained
regularly?
Outdoor unit test
• Is there any abnormal noise or
vibration during operation?
• Could the noise, airflow or condensed
water drainage disturb the
neighbours?
• Is there any coolant leakage?
NOTE:
The electronic controller starts the compressor
three minutes after voltage has reached the system.
Suction Valve
Service Port Nut
Indoor Unit
Liquid Valve
Protection Caps
NOTE: The electronic controller starts the compressor
three minutes after voltage has reached the system.
24
27