Part2 - Remote Setup
20
Port/QoS
Use/Port: Enable/disable ports and designate
corresponding port numbers. Remote Port and IDIS
Web / HTTP ports are enabled by default and cannot
be disabled. By enabling IDIS Web and RTSP ports, you
will be able to use the IDIS Web program or a media
player that supports RTSP (Real-Time Streaming
Protocol) service to connect to the encoder. When
the HTTP port is enabled, you can run the encoder’s
Remote Setup. If this option has been changed, click
Save to apply the current settings, and then restart
Remote Setup. If you do not restart Remote Setup, the
changes afterwards will not be applied.
DSCP: Designate each port’s QoS (Quality of Service)
level using DSCP values. Assigning QoS levels
prioritizes the ports for network bandwidth use.
Higher the DSCP value, higher the QoS level and thus
higher on the network bandwidth allocation priority
list. Use 0
if you do not want to assign a QoS level. The
network environment must support DSCP in order
for this feature to function properly. Contact your
network administrator for more details.
Use HTTPS: Select this option to apply https protocol-
based security on IDIS Web.
Use UPn
P: If the encoder is connected to the network
via an IP router (or NAT), select t
his option to connect
to the encoder without setting up port forwarding.
The IP router (or NAT) must be enabled with UPnP in
order for this feature to function properly. For more
information enabling UPnP on your IP router (or NAT),
refer to the IP router or NAT’s operation manual.
Click Check to test the current port settings.
A conrmation message will appear if all the
selected ports are available for use. If not, a list of
recommended port numbers will be shown.
Click Apply to use the recommended port numbers.