Icron Polaris 7044 handleiding
Handleiding
Je bekijkt pagina 10 van 24

DESCRIPTION ACCOUNT LEVEL COMMAND EXAMPLES
Switch USB input to
Multiple Outputs
User/Admin User:
C<space>I<input>O<output>
Input:
0 – Clear all Host Connections
A – Host A
B – Host B
C – Host C
D – Host D
Output:
1 - Device 1
2 - Device 2
3 – Device 3
4 – Device 4
Response:
SWITCH-I<Input>O<output>,<output>..
Command:
C IBO4<CR><LF>
Response:
SWITCH-IBO4,2<CR><LF>
Switches Host B to Output 4
and 2
To Clear all, Set input to 0
Query USB Input User/Admin User:
INPUT<space>-?<space><output>
Output:
1 - Device 1
2 - Device 2
3 – Device 3
4 – Device 4
Response:
SWITCH-I<Input>O<output>
Command:
INPUT -? 4<CR><LF>
Response:
SWITCH-IBO4<CR><LF>
Query USB Output User/Admin User:
OUTPUT<space>-?<space><input>
Input:
A
B
C
D
Response:
SWITCH-I<Input>O<output>,<output>
Command:
OUTPUT -? B<CR><LF>
Response:
SWITCH-IBO4,2<CR><LF>
10