MAINTENANCE
■ Troubleshooting
The following chart is designed to help correct prob-
lems which are not equipment malfunctions.
If you are unable to locate the cause of a problem or
solve it through the use of this chart, contact the near-
est Icom Dealer or Service Center.
■ Fuse replacement
If a fuse blows, and the repeater stops functioning, find
the source of the problem, repair it, and then replace
the damaged fuse with a new matching rated fuse.
CAUTION: DISCONNECT the DC power cable from
the repeater. Otherwise, there is danger of an elec-
tric shock and/or equipment damage.
D Line fuse replacement
PROBLEM POSSIBLE CAUSE SOLUTION REF.
Power does not come
on when [POWER] is
pushed.
•ThepowersupplyisturnedOFF.
•DCpowercableisimproperlyconnected.
•Fuseisblown.
•TurnONthepowersupply.
•ReconnecttheDCpowercablecorrectly.
•Checkthecause,repairit,andthenreplace
the fuse with a compatible one.
—
pp. 6, 7
p. 9
No sounds are heard
from the speaker.
•Volumelevelistoolow.
•Thesquelchisclosed.
•Theaudiomutefunctionisactivated.
•Aselectivecallorsquelchfunctionsuchas
5 tone call or tone squelch is activated.
•ThefrontspeakeristurnedOFF.
•ThefunctionassignedtothepinsoftheACC
connector is wrong.
•Rotate[VOLUME] clockwise to obtain a suit-
able listening level.
•Whileinthebaseoperatingmode,rotate
[SELECT] counterclockwise to open the
squelch. (When the [SQL Level Up/Down]
key function is assigned to [SELECT].)
•Push[MONI] (if assigned) to turn OFF the
audio mute function.
•TurnOFFtheappropriatefunction.
•Turn ONthefront speakerusingthe CS-
FR5000(dPMR)
cloning software. Ask
your dealer for details.
•AssignthecorrectfunctionusingtheCS-
FR5000(dPMR). Ask your dealer for details.
p. 8
p. 8
—
—
—
p. 4
Sensitivity is low and
only strong signals
are audible.
•Antennafeedlineortheantennaconnector
has poor contact or is shorted.
•Checktheantennacableorconnectorand
then reconnect, or replace if necessary.
pp. 6, 7
Received signal can-
not be understood.
•OptionalvoicescrambleristurnedOFF.
•Scramblercodeisnotcorrectlyset.
•TurnONtheoptionalvoicescrambler.
•Resetthescramblercode.
—
—
Output power is too
low.
•OutputpowerissettoLow.
•Poweramplifier protection circuit is acti-
vated.
•ThefunctionassignedtothepinsoftheACC
connector is wrong.
•Push[HIGH/LOW] (if assigned) to select
High power.
•Cooldowntherepeaterorstopaccessing
the repeater until it has cooled down.
•AssignthecorrectfunctionusingtheCS-
FR5000(dPMR). Ask your dealer for details.
—
—
p. 4
No contact possible
with another station.
•Theotherstationisusingtonesquelch.
•Whileoperatinginthebasemode,there-
peater is set to duplex.
•TurnthetonesquelchfunctionON.
•Settherepeatertosimplex,whentheother
transceiver is set to simplex.
—
—
The transmit signal
is not output from the
PA unit.
•Poweramplierprotectioncircuitisactivated
because the repeater unit’s output power
level is set too high, or too low.
•Adjusttherepeater’soutputpowerlevelto
5 W.
—
The PA unit tempera-
ture data cannot be
detected.
•ThefunctionassignedtothepinsoftheACC
connector is wrong.
•AssignthecorrectfunctionusingtheCS-
FR5000(dPMR). Ask your dealer for details.
p. 4
Fuse rating: 20 A (for the repeater unit),
30 A (for the PA unit)
USE the specified fuse only.