Hymer Exsis I (2025) handleiding

240 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 98 van 240
7 Gas system
98 Exsis I/T - 01/23-1 - EHG-0027-02EN
7.3 Gas isolator taps
1 Cooker
2 Hot water
3 Refrigerator
4 Oven/grill
5 Heater
6 Hot water/heater
Fig. 88 Possible symbols for the
gas isolator taps
A gas isolator tap (Fig. 88) for every gas device is built into the vehicle. The
gas isolator taps can be found under the cooker.
1 Gas isolator tap open
2 Gas isolator tap closed
3 Gas pipe
4 Pipe to the gas device
Fig. 89 Gas isolator taps position
(example)
Position the gas isolator tap of the corresponding gas device parallel
(Fig. 89,1) to the pipe (Fig. 89,4) leading to the gas device.
Position the gas isolator tap of the corresponding gas device transverse
(Fig. 89,2) to the pipe (Fig. 89,4) leading to the gas device.
7.4 External gas connection
If the external gas connection is not in use, always close the gas isola-
tor tap.
Only gas appliances with a suitable adapter should be connected to
the external gas connection.
Connect only external gas appliances which are designed for an oper-
ation pressure of 30 mbar.
Once you have made the connection and opened the gas isolator tap,
make sure that no gas is escaping at the connection point. If there is a
leak in the external gas connection, gas will escape into the open air.
Immediately close the gas isolator tap and the regulator tap on the
gas bottle. Have the external gas connection checked by an author-
ised specialist workshop.
When connecting an external gas appliance, make sure that there is
nothing near the external gas connection that could cause a spark.
Opening:
Closing: