Safety 2
Exsis I/T - 01/23-1 - EHG-0027-02EN 17
Do not use gas-operated devices in closed spaces (e.g. garages).
Danger of poisoning and suffocation!
Only have the gas system maintained, repaired or altered by an au-
thorised specialist workshop.
Have the gas system checked by an authorised specialist workshop
according to the national regulations before commissioning. This also
applies for not registered vehicles. For modifications to the gas sys-
tem have the gas system immediately checked by an authorised spe-
cialist workshop.
The gas pressure regulator, the gas tubes, and the exhaust gas pipes
must also be inspected. The gas pressure regulator and the gas tubes
must be replaced observing the nationally defined deadlines (the lat-
est after 10 years). The vehicle owner is responsible for seeing that
this is carried out.
In case of a defect of the gas system (gas odour, high gas consump-
tion) there is danger of explosion! Close regulator tap on the gas bot-
tle immediately. Open doors and windows and ventilate well.
If the gas system is defective: Do not smoke; do not ignite any open
flames, and do not operate electric switches (light switches etc.).
Check the tightness of gas-conducting parts and lines with leakage
search spray. Do not check with an open flame.
Only the stipulated devices may be connected to internal connections.
Do not operate any device outside the vehicle if it is connected to an
internal connector.
Before using the cooker make sure that there is sufficient ventilation.
Open a window or the skylight.
Cooking is prohibited during the journey.
Do not use gas-operated cooking and baking facilities for heating pur-
poses.
If there are several gas devices, each gas device must have its own
gas isolator tap. If individual gas devices are not in use, close the re-
spective gas isolator tap.
Ignition safety valves must close within 1 minute after the gas flame
has extinguished. A clicking sound is audible. Check function from
time to time.
The built-in gas devices are exclusively meant for use with propane or
butane gas or a mixture of both. The gas pressure regulator as well as
all built-in gas devices are designed for a gas pressure of 30 mbar.
Propane gas is capable of gasification up to -42 °C, whereas butane
gas gasifies at 0 °C. Below these temperatures no gas pressure is
available. Butane gas is unsuitable for use in winter.
Due to its function and construction, the gas bottle compartment is a
space which is open to the exterior. Never cover or block up the
standard forced ventilations. Otherwise gas that is emitted can not be
diverted to the outside.
The gas bottle compartment must not be used as storage space.
Secure the gas bottle compartment against unauthorised access. To
do this, lock the compartment.
The regulator tap on the gas bottle must be accessible.