Electrical system 8
B-MC I/T - 01/23-1 - EHG-0016-03EN 133
Charge the battery for at least 48 hours after a total discharge.
At temperatures below 0 °C, a living area battery consumes less power.
At approx. -15 °C, there will be no more power. The living area battery
can no longer be charged.
Always connect the load and charging lines cross-wise. This is neces-
sary to ensure the batteries always have the same line resistance to one
another. This allows the charging/discharging current to be distributed
equally.
This section contains instructions on the storage of the living area battery.
◼ Store the disconnected battery in a cool and dry place.
◼ In the case of a disconnected, fully charged gel battery it may suffice to
recharge the battery after 6 months.
Recommendation: Also charge a gel battery for 24 to 48 hours every 4 to
6 weeks.
If there is an "intelligent" charger with float charge functionality, have the
charger connected to the battery and switched on over the entire lay-up
time.
Fig. 139 Connecting auxiliary battery
To ensure that all batteries are charged or used up equally, the batteries are
connected according to Fig. 139.
Storage
Installation of auxiliary
battery