Hydra Kool KPM-OF handleiding
Handleiding
Je bekijkt pagina 15 van 34

54
For easier cleaning remove the front glass (instructions below).
5.2 Interior cleaning
All operations must be done with the unit disconnected.
Clean surfaces (glass/metal/plastic) with soft detergent or warm water. Do not use
abrasive cleanser.
5.3 Shelf removing
All operations must be done with the unit disconnected.
To remove or adjust shelves take care with light connections.
15
KPM series intended for deli, meat and fish are type 1 equipment - 75°F/55%RH.
Temperature of the deli and meat cases is set for 32°F.
The decks have a 31 lb/ft
loading limit.
Glass shelves are for non refrigerated products only and have a 5,5 lb/ft
loading limit.
Model
Dimensions
(LxDxH in inches)
Service
dimensions
(LxDxH in inches)
9,3/5,33
12,1/8,76
16,0/13,41
9,3/5,33
12,1/8,76
16,0/13,41
9,3/5,33
12,1/8,76
16,0/13,41
Volume (ft³)
60¹⁄'' x 49⁹⁄'' x 61⁄''
77⁹⁄'' x 49⁹⁄'' x 61⁄''
101⁄'' x 49⁹⁄'' x 61⁄''
60⁄'' x 44¹⁄'' x 61⁄''
77⁹⁄'' x 44¹⁄'' x 61⁄''
101⁄'' x 44¹⁄'' x 61⁄''
60⁄'' x 34¹¹⁄'' x 61⁄''
77⁹⁄'' x 34¹¹⁄'' x 61⁄''
101⁄'' x 34¹¹⁄'' x 61⁄''
60¹⁄'' x 49⁹⁄'' x 75⁄''
77⁹⁄'' x 49⁹⁄''
x 75⁄''
101⁄'' x 49⁹⁄'' x 75⁄''
60¹⁄'' x 44¹⁄'' x 82⁄''
77⁹⁄'' x 44¹⁄'' x 82⁄''
101⁄'' x 44¹⁄'' x 82⁄''
60¹⁄'' x 34¹¹⁄'' x 62¹¹⁄''
77⁹⁄'' x 34¹¹⁄'' x 62¹¹⁄''
101⁄'' x 34¹¹⁄'' x 62¹¹⁄''
KPM-CG-60-S(R)(D)
KPM-CG-80-S(R)(D)
KPM-CG-100-S(R)(D)
KPM-FG-60-S(R)(D)
KPM-FG-80-S(R)(D)
KPM-FG-100-S(R)(D)
KPM-OF-60-S(R)(D)
KPM-OF-80-S(R)(D)
KPM-OF-100-S(R)(D)
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 Getting started with your KPM series
2.1 Location
To your new equipment perform well please respect the following warnings:
This is type 1 equipment, intended to work with 75°F / 55%RH.
This equipment is intended for maintaining temperature only.
Be sure products are not ambient temperature (must be cold)
This equipment must be located in an indoor environment.
Check for airdrafts and avoid them.
Air movement from ac units shouldn’t be directed to the equipment.
The equipment must not be directly or indirectly exposed to the sun.
Check for rejected heat from another refrigeration units and avoid that.
Place the equipment in a levelled floor.
Do not obstruct the air way in front of the condenser.
Make sure there is a drain preparation (remotes and fish display cases only).