6 Troubleshooting/Service
6.1 Troubleshooting
Service must be performed by a qualified technician.
Doors not closing:
Check for leveled floor.
Check
for obstruction.
Remove doors and check the bearings.
Lights not working:
Check light switch position.
Check
light connections.
Warm case temperature:
Check for air return grille obstruction.
Check for air drafts.
Check
store temperature.
Check for condenser obstruction and cleaning.
Check for frozen evaporator.
Check
set point.
Display area is over filled.
Fans not working:
Check electrical connections.
Check for any debris.
Case not aligning:
Check for leveled floor.
Check instructions for joining.
Display not working:
Check main power switch position..
Check
electrical connections.
Compressor not starting:
Disconnect switch open.
Blo
wn fuse.
Ov
erload protective tripped.
Low charge of refrigerant.
R
elay defective.
9