WARP X - MANUAL
13
13
ENGLISH
66..00 PPOOSSSSIIBBLLEE EERRRROORR SSOOUURRCCEESS //
TTRROOUUBBLLEESSHHOOOOTTIINNGG
THE WARP X™ WON’T POWER UP WHEN YOU
SWITCH IT ON:
• It‘s not getting AC power. Check the mains cable to
see if it‘s connected properly.
• The mains fuse is defective. Ensure it is replaced with
another fuse of the same rating.
THE WARP X™ IS CONNECTED PROPERLY, BUT NO
SOUND IS AUDIBLE:
• The amp is set to STANDBY
• One or several GAIN and MASTER controls are turned
all the way down
• The anode fuse has tripped. Before replacing the fuse
with another fuse of the same rating, have the power
tubes checked to learn if they are defective.
• The fuse for the tube heater has tripped
(the tubes don’t glow). When replacing this fuse, make
absolutely certain that it is replaced with a fuse bearing
the same rating. Be sure to have a service technician
replace the fuse.
THE FX LOOP IS ON WHEN IT SHOULDN’T BE:
• The FX LOOP is deactivated when the front panel
button, the Stageboard button and the MIDI module
switching function are off. If any of these three switches
is on, the FX LOOP is active.
THE SOUND IS THIN AND MUDDY WHEN YOU SWITCH
AN EFFECTS PROCESSOR ON.
• The signal processor provides a wet signal that is
blended with the dry or original signal. Depending on
the type of effect, the processor may be returning a
dry signal back along with wet signal, which causes
phase cancellations when mixed to the dry signal in
the WARP X™’s parallel loop. To prevent phase cancel-
lations, switch the FX LOOP to SERIAL or turn the dry
signal all the way down on the signal processor.
YOUR AMP IS PRODUCING RINGING NOISES OR
TENDS TO FEEDBACK:
• One or several tubes are microphonic. Replace the
defective tube with another of the same type.
AFTER JUST A FEW HOURS OF OPERATION, YOUR
AMP IS DISPLAYING THE TYPICAL CHARACTERISTICS
OF OLD TUBES (INCREASED MICROPHONICS AND
NOISE, TREBLE LOSS, WEAK POWER OUTPUT, MUDDY
SOUND):
• The wrong tubes were installed when old tubes were
replaced or the amp was not biased properly. Take the
amp to a professional amp technician to correct the
problem.