Hughes & Kettner TubeMeister 36 handleiding
Handleiding
Je bekijkt pagina 16 van 80

16
Press and hold the two ON buttons for FX LOOP
and REVERB simultaneously for more than three
seconds to save the settings and quit MIDI setup
mode. The buttons will stop flashing to indicate the
amp is back in normal operating mode.
3.3 Factory Settings and How to
Restore Them (Factory Reset)
To reset the amp to the factory default settings,
press and hold the REVERB ON and FX LOOP
ON while powering up simultaneously until the
MIDI LEARN button lights up. After you release
the ON buttons, MIDI LEARN will flash once
to confirm that the reset has been executed properly.
The factory defaults are:
• OMNI ON
• MIDI Channel 1
The factory default settings and assignments for
sounds are:
MIDI
Program
Preamp
Channel
Power
Output
FX
Loop REVERB
1Clean36 WOFFON
2 Crunch 36 W OFF OFF
3 Lead 36 W OFF OFF
4Clean0 WOFFOFF
5Clean18 WOFFON
6 Crunch 18 W OFF OFF
7 Lead 18 W OFF OFF
8Clean0 WOFFOFF
9Clean5 WOFFON
10 Crunch 5 W OFF OFF
11 Lead 5 W OFF OFF
12 Clean 0 W OFF OFF
13 Clean 1 W OFF ON
14 Crunch 1 W OFF OFF
15 Lead 1 W OFF OFF
16 Clean 0 W OFF OFF
4 Tube Safety Control (TSC™)
TSC™ adjusts bias to improve the amp’s tonal and
technical stability and extend power tubes’ life. It
does this automatically and continuously, so there is
nothing for you to do but enjoy the convenience.
Swapping tubes is more easily, quickly, and safely
done than with a conventional amp. This is a big
help not only in case of a defect, but also when you
want to compare different brands of replacement
tubes.
CAUTION: Replacing tubes is a job for qualified
professionals! TSC™ merely spares the technician the
biasing effort.
What do the LEDs indicate?
Each LED is assigned to the power tube occupying
that same position. Getting a read-out of tubes’
operating status and bias points is easy using any
standard guitar pick.
4.1 Automatic Status Indications:
All LEDs Light Up And Stay On
All LEDs remain on for as long as the amp is in
standby mode. When you flip the STANDBY
switch to PLAY, they will extinguish after about 30
seconds. If the LEDs remain illuminated, the most
likely cause is a blown anode fuse that needs to be
replaced by a technician. The anode fuse can trip if
a tube is already defective when the amp is switched
on, and TSC does not have enough time to measure
idle current and shut the faulty tube down.
None of the LEDs Lights Up
The power tubes are operating normally.
One LED Lights Up Continuously
The tube assigned to this LED is not delivering
enough current and has been shut down. If the LED
does not extinguish after a few minutes, this tube
must be replaced.
Bekijk gratis de handleiding van Hughes & Kettner TubeMeister 36, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Hughes & Kettner |
| Model | TubeMeister 36 |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 17103 MB |







