Huawei SUN2000-15KTL-M5 handleiding

97 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 70 van 97
Alarm
ID
Alarm
Name
Alarm
Severity
Possible Causes Troubleshooting
2064 Device
fault
Major Cause ID = 1–5, 7–
12
An unrecoverable
fault occurs on a
circuit inside the
inverter.
Turn o the AC output switch and DC
input switch, and then turn them on
after 5 minutes. If the alarm persists,
contact your dealer or Huawei technical
support.
NOTICE
Cause ID = 1: Perform the preceding
operations when the PV string current is less
than 1 A.
2065 Upgrade
failed or
version
mismatch
Minor Cause ID = 1–4, 7
The upgrade is not
completed
normally.
1. Perform an upgrade again.
2. If the upgrade fails several times,
contact your dealer or Huawei
technical support.
61440 Faulty
monitorin
g unit
Minor Cause ID = 1
The ash
memory is
insucient.
The ash
memory has bad
sectors.
Turn o the AC output switch and DC
input switch, and then turn them on
after 5 minutes. If the alarm persists,
replace the monitoring board or contact
your dealer or Huawei technical support.
2067 Faulty
power
collector
Major Cause ID = 1
The power meter is
disconnected.
1. Check whether the congured power
meter model is the same as the
actual model.
2. Check whether the communications
parameters of the power meter are
the same as the RS485
congurations
of the inverter.
3. Check whether the power meter is
powered on and whether the RS485
communications cable is connected.
SUN2000-(12KTL-25KTL)-M5 Series
User Manual 8 Maintenance
Issue 01 (2022-06-15) Copyright © Huawei Digital Power Technologies Co., Ltd. 64