LOCK FEATURE
: Press together “Fan” and “Swing” buttons at the same time for one second to
activate Lock function. All buttons will not response except pressing these two buttons again to
disable locking. If you press any other button on the display panel, the lock symbol “ ” will flash
5 times at 1Hz. Under Lock mode , the remote control is available.
Electric heating function (some models):
Under heating mode, the electrical heating feature is activated automatically, and the electrical
heating symbol “ ” illuminates. Turn off the unit or start the sleep operation will cancel this
function.
Test Run operation
: When the unit is on , press together " Mode “ and ”Swing" buttons at the
same time for one second to activate test run operation. Turning off the unit , pressing “Mode” and
“Swing” buttons for one second again or the test run operation lasting for 30 minutes will stop the
test run operation.
Under test run operation, all the buttons are disable except “Power”, “ ” and “ ” buttons.
The remote control is also unavailable. The LED display is turned on.
NOTE: This function can only be activated by remote controller. This function is not available
under Auto mode.
Under test run operaiton, press “ ” and “ ” buttons can display the temperature of T1, T2,
T3 and T4 , the protection or error codes. The sensor malfunction can also be detected.