22
ALARM INDICATORS
Error Reason Action
E1 -E1
E2 -E2
E3 -E3
The probe may be interrupted
(E ) or in short circuit ( -E ) or
may measure a value outside
the range allowed
Check the probe connection
with the instrument and
check that the probe works
correctly
epr
Internal EEPROM memory
error
Press the
/ key
err
Fatal memory error
Replace the control module
or ship to factory for repair
Message Reason
od
Delay at power-on in progress
Ln
Keyboard locked
Hi
Maximum temperature alarm in progress
Lo
Minimum temperature alarm in progress
AL
Digital Input alarm in progress
oP
Door Open
dEF
Defrost in progress with ddL = Lb
PdF
Post-defrosting in progress with ddL = Lb
Eco
Eco Mode in progress
trb
Turbo Mode in progress
OTHER MESSAGES
TEMPERATURE SELECTION
TEMPERATURE
0°F to +9°F (-18°C to -13°C)
+38°F to +42°F (+3°C to +5°C)
FREEZER
REFRIGERATOR
HOW TO SEE AND CHANGE THE SET POINT
By pressing and releasing the or key, the control module will display
the current set-point value. Pressing the or key again will allow you
to select the desired value by moving up or down. Once the desired value
has been selected, press the / key or wait 10 seconds, aer which
the control module will acvate the new set-point value and the display
will return to normal operaon mode.