2.Freezers
Heated Defrost: Freezers utilize a temperature or time initiated heated defrost.
Note: There is a 1-hr. defrost lock-out after a defrost cycle terminates. This may be
bypassed by initiating a manual defrost or unplugging and plugging back in to the
electrical outlet.
• Temperature Initiated: When the defrost thermistor is at or below -32°F (-35.5°C),
defrost starts.
• Time Initiated:
a) Cumulative Compressor Run Time: Once the 12-hr. Cumulative Compressor Run
Timer terminates, defrost starts.
b) Continuous Compressor Run Time: Once the 4hr. Continuous Compressor Run
Timer terminates, defrost starts.
The maximum defrost time is 1 hr.
• When defrost initiates, the maximum 1-hr. defrost timer starts. Compressor and
condenser fan motor de-energize. Evaporator fan motor remains energized.
• When the defrost thermistor reaches 55°F (12.7°C), or the maximum 1-hr. defrost
timer terminates, defrost terminates. Evaporator fan motor remains energized and
compressor and condenser fan motor energize.
3. Defrost Display
a) Refrigerator Display: During defrost "dEF" is displayed. The compressor icon turns
off and the evaporator fan motor icon continues. Once defrost termination temperature
is achieved or the maximum timer times out, defrost terminates. The compressor icon
turns on, the evaporator fan motor icon continues and PdF is displayed. PdF continues
until the cabinet temperature achieves 2.7°F (1.5°C) above temperature setpoint or the
15-min. timer terminates. Once 2.7°F (1.5°C) above temperature setpoint is achieved
or the 15-min. timer terminates, the cabinet temperature returns to display.
b) Freezer Display: During defrost "dEF" is displayed. The comprerssor and evaporator
fan motor icons turn off. Once defrost termination temperature is achieved or the
maximum timer times out, defrost terminates. The defrost icon starts ashing, PdF is
displayed, and the 3-min. drip timer starts. Once the 3-min. drip timer terminates, the
defrost icon turns off, the compressor and evaporator fan motor icons turn on, and
PdF continues. PdF continues until the cabinet temperature achieves 2.2°F (1.2°C)
above temperature setpoint or 15-min. timer terminates. Once 2.2°F (1.2°C) above
temperature setpoint is achieved or 15-min. timer terminates, the cabinet temperature
returns to display.
4. Defrost Termination
Defrost Termination Temperature:
Refrigerator: 45°F (7.2°C)
Freezer: 55°F (12.7°C)
Example: After the refrigerator defrost thermistor warms to 45°F (7.2°C), defrost
terminates.
5. Manual Defrost
To initiate a manual defrost, press and hold the up button for 5 seconds.
To terminate a defrost, press and hold the up button for 5 seconds. Note: Manual defrost
only initiates when evaporator temperature (defrost thermistor) is at or below 45°F (7.2°C)
for refrigerators and 56°F (13.3°C) for freezers.