F. Cabinet Control Alarm Safeties
Alarm signals are designed to protect the appliance and food product. These alarms
give information or warnings in the event the appliance is operating out of acceptable
parameters. Should one of the alarms occur, follow the instructions in the table below to
address the alarm. The alarm code and alarm icon ash with audible alarm.
Alarm Signals
Alarm Code Problem Corrective Action/Reset Details
(-)E1
Cabinet Thermistor Malfunction
Alarm
Cabinet thermistor has failed.
Call a qualied service technician.
Steady tone. To silence the alarm, press and release
any button.
Refrigerator: Appliance cycles 4 min. on, 6 min. off.
Freezer: Appliance cycles 6 min. on, 3 min. off.
-E1 - Cabinet thermistor out of place or open.
E1 - Cabinet thermistor shorted.
(-)E2
Defrost Thermistor Malfunction
Alarm
Defrost thermistor has failed.
Call a qualied service technician.
Steady tone. To silence the alarm, press and release
any button.
Appliance cycles on and off with cabinet thermistor.
Refrigerator: Defrost cycles for 20 min. every 12 hrs.
Freezer: Defrost cycles for 15 min. every 5 hrs.
-E2 - Defrost thermistor out of place or open
E2 - Defrost thermistor shorted.
Hi
High Temperature Alarm
Refrigerator: Cabinet temperature
has remained above 53°F (11.6°C)
for more than 1 hour.
Freezer: Cabinet temperature has
remained above 32°F (0°C) for
more than 1 hour.
If obvious corrections such as closing drawers and
cleaning the air lter and/or condenser do not bring
temperature back in range, call a qualied service
technician.
Steady tone. To silence the alarm and clear "Hi" from
the display, press and release any button. The alarm
icon stays on.
Automatically resets when temperature returns to
normal.
Lo
Low Temperature Alarm
Refrigerator: Cabinet temperature
has remained below 20°F (-6.7°C)
for more than 1 hour.
Freezer: Cabinet temperature has
remained below -30°F (-34.4°C) for
more than 1 hour.
If obvious corrections do not bring the temperature
back in range, call a qualied service technician.
Steady tone. To silence the alarm and clear "Lo"
from the display, press and release any button. The
alarm icon stays on.
Automatically resets when temperature returns to
normal.
UHi
High Voltage Alarm (140VAC ± 5%
or more)
The compressor de-energizes if voltage protection
operates.
The voltage safeties automatically reset when
voltage is corrected.
ULo
Low Voltage Alarm (100VAC ± 5%
or less)