F. Cabinet Control Alarm Safeties
No alarms are available for the rail control module. The cabinet control module is the
only control with alarm capabilities. Alarm signals are designed to protect the appliance
and food product. These alarms give information or warnings in the event the appliance
is operating out of acceptable parameters. Should one of the alarms occur, follow the
instructions in the table below to address the alarm. The alarm code and alarm icon ash
with audible alarm.
Alarm Signals
Alarm Code Problem Corrective Action/Reset Details
(-)E1
Cabinet Thermistor Malfunction Alarm
Cabinet thermistor has failed.
Call a qualied service technician.
Steady tone. To silence the alarm, press and release
any button.
Appliance cycles 5 min. on, 5 min. off.
-E1 - Cabinet thermistor out of place or open.
E1 - Cabinet thermistor shorted.
Hi
High Temperature Alarm
Cabinet temperature has remained
above 57°F (13.9°C) for more than
1hour.
If obvious corrections such as closing doors/drawers
and cleaning the air lter and/or condenser do not
bring temperature back in range, call a qualied
service technician.
Steady tone. To silence the alarm, press and release
any button. The alarm icon stays on.
Automatically resets when temperature returns to
normal.
Lo
Low Temperature Alarm
Cabinet temperature has remained
below 20°F (-6.6°C) for more than
1hour.
If obvious corrections do not bring the temperature
back in range, call a qualied service technician.
Steady tone. To silence the alarm, press and release
any button. The alarm icon stays on.
Automatically resets when temperature returns to
normal.