F. Alarm Safeties
Alarm signals are designed to protect the appliance and food product. These alarms
give information or warnings in the event the appliance is operating out of acceptable
parameters. Should one of the alarms occur, follow the instructions in the table below to
address the alarm. The alarm code and alarm icon ash with audible alarm.
Alarm Signals
Alarm Code Problem Corrective Action/Reset Details
(-)E1
Cabinet Thermistor Malfunction Alarm
Cabinet thermistor has failed.
Call a qualied service technician.
Steady tone. To silence the alarm, press and release
any button.
Appliance cycles 5 min. on, 5 min. off.
-E1 - Cabinet thermistor out of place or open.
E1 - Cabinet thermistor shorted.
(-)E2
Defrost Thermistor Malfunction Alarm
Defrost thermistor has failed.
Call a qualied service technician.
Steady tone. To silence the alarm, press and release
any button.
Appliance cycles on and off with cabinet thermistor.
Defrost cycles for 10 min. every 6 hrs.
-E2 - Defrost thermistor out of place or open.
E2 - Defrost thermistor shorted.
Hi
High Temperature Alarm
Cabinet temperature has remained
above 57°F (13.9°C) for more than
1hour.
If obvious corrections such as closing drawers and
cleaning the air lter and/or condenser do not bring
temperature back in range, call a qualied service
technician.
Steady tone. To silence the alarm and clear "Hi" from
the display, press and release any button. The alarm
icon stays on.
Automatically resets when temperature returns to
normal.
Lo
Low Temperature Alarm
Cabinet temperature has remained
below 10°F (-12°C) for more than
1hour.
If obvious corrections do not bring the temperature
back in range, call a qualied service technician.
Steady tone. To silence the alarm and clear "Lo" from
the display, press and release any button. The alarm
icon stays on.
Automatically resets when temperature returns to
normal.
UHi
High Voltage Alarm (140VAC±5% or
more)
Call a qualied service technician.
The compressor de-energizes if voltage protection
operates. The voltage safeties automatically reset when
voltage is corrected.
ULo