Model Number F3A-FS(-HS)
AC SUPPLY VOLTAGE ~115/60/1
AMPERES 11
DESIGN PRESSURE kPa (PSI) HI-2482 (360) LO-1310 (190)
REFRIGERANT g (oz.) R-290 115 (4.1)
CLIMATIC CLASS 5
INSULATION BLOWING GAS HFO 1233zd(E)
MINIMUM ROOM FLOOR AREA m² (ft² ) 5.5 (59.2)
Model Number DT1A-HS
Refrigerator Freezer
AC SUPPLY VOLTAGE ~115/60/1 ~115/60/1
AMPERES 5.5 5.5
DESIGN PRESSURE kPa (PSI) HI-2482 (360) LO-1310 (190) HI-2482 (360) LO-1310 (190)
REFRIGERANT g (oz.) R-290 60 (2.1) R-290 70 (2.5)
CLIMATIC CLASS 5 5
INSULATION BLOWING GAS HFO 1233zd(E) HFO 1233zd(E)
MINIMUM ROOM FLOOR AREA m² (ft² ) 3.3 (36.1) 3.3 (36.1)
Model Number DT2A-FS/HS
Refrigerator Freezer
AC SUPPLY VOLTAGE ~115/60/1 ~115/60/1
AMPERES 14 14
DESIGN PRESSURE kPa (PSI) HI-2482 (360) LO-1310 (190) HI-2482 (360) LO-1310 (190)
REFRIGERANT g (oz.) R-290 130 (4.6) R-290 115 (4.1)
CLIMATIC CLASS 5 5
INSULATION BLOWING GAS HFO 1233zd(E) HFO 1233zd(E)
MINIMUM ROOM FLOOR AREA m² (ft² ) 6.2 (67) 6.2 (67)
Note: Climatic Class 5: This appliance electrical safety tested for operation in maximum
ambient temperature of 104°F (40°C) with 40% relative humidity. However,
normal operating ambient temperature for refrigerator and solid door freezers
must be within 45°F to 100°F (7°C to 38°C) and for glass door freezers 45°F to
80°F (7°C to 27°C). Operation of the appliance, for extended periods, outside of
these normal temperature ranges may affect appliance performance.