Hoshizaki Steelheart F2A-FSN handleiding

56 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 12 van 56
12
Model Number F3A-FS(-HS)
AC SUPPLY VOLTAGE ~115/60/1
AMPERES 11
DESIGN PRESSURE kPa (PSI) HI-2482 (360) LO-1310 (190)
REFRIGERANT g (oz.) R-290 115 (4.1)
CLIMATIC CLASS 5
INSULATION BLOWING GAS HFO 1233zd(E)
MINIMUM ROOM FLOOR AREA m² (ft² ) 5.5 (59.2)
Model Number DT1A-HS
Refrigerator Freezer
AC SUPPLY VOLTAGE ~115/60/1 ~115/60/1
AMPERES 5.5 5.5
DESIGN PRESSURE kPa (PSI) HI-2482 (360) LO-1310 (190) HI-2482 (360) LO-1310 (190)
REFRIGERANT g (oz.) R-290 60 (2.1) R-290 70 (2.5)
CLIMATIC CLASS 5 5
INSULATION BLOWING GAS HFO 1233zd(E) HFO 1233zd(E)
MINIMUM ROOM FLOOR AREA m² (ft² ) 3.3 (36.1) 3.3 (36.1)
Model Number DT2A-FS/HS
Refrigerator Freezer
AC SUPPLY VOLTAGE ~115/60/1 ~115/60/1
AMPERES 14 14
DESIGN PRESSURE kPa (PSI) HI-2482 (360) LO-1310 (190) HI-2482 (360) LO-1310 (190)
REFRIGERANT g (oz.) R-290 130 (4.6) R-290 115 (4.1)
CLIMATIC CLASS 5 5
INSULATION BLOWING GAS HFO 1233zd(E) HFO 1233zd(E)
MINIMUM ROOM FLOOR AREA m² (ft² ) 6.2 (67) 6.2 (67)
Note: Climatic Class 5: This appliance electrical safety tested for operation in maximum
ambient temperature of 104°F (40°C) with 40% relative humidity. However,
normal operating ambient temperature for refrigerator and solid door freezers
must be within 45°F to 100°F (7°C to 38°C) and for glass door freezers 45°F to
80°F (7°C to 27°C). Operation of the appliance, for extended periods, outside of
these normal temperature ranges may affect appliance performance.

Bekijk gratis de handleiding van Hoshizaki Steelheart F2A-FSN, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkHoshizaki
ModelSteelheart F2A-FSN
CategorieVriezer
TaalNederlands
Grootte5596 MB