Hoshizaki KMH-2100SRJZ3 handleiding

39 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 33 van 39
33
Cleaning
4) Remove the front insulation panel, then remove the drain plug. See Fig. 19. After the
water tank has drained, replace the drain plug and front insulation panel.
NOTICE!Be careful not to cross thread the drain plug.
5) To ll the water tank, move the control switch to the "ICE" position, then replace the front
panel. After 3 min., remove the front panel, then move the control switch to the "OFF"
position.
6) Remove the front insulation panel, then pour Hoshizaki "Scale Away" into the water
tank. Seetable below for amount. Replace the front insulation panel. Turn the cleaning
valve to the left until completely vertical (open).
Model Scale Away
KM-1900 and Larger 43 . oz. (1,272 ml)
7) NOTICE! To avoid excessive foaming, wait 1min. before proceeding.
After 1 min., move the control switch to the "WASH" position, then replace the front
panel.
8) After 30 min., remove the front panel, then move the control switch to the "OFF"
position.
9) Remove the front insulation panel, then remove the drain plug. After the water tank has
drained, replace the drain plug and front insulation panel.
10) In bad or severe water conditions, turn off the power supply, then remove, clean
(cleaning solution = 5 oz. Hoshizaki "Scale Away" per gallon of warm water), rinse, and
replace the cube guide, oat switch, water supply tubes, spray tubes, and spray guides;
turn on the power supply when complete. Otherwise, continue to step 11.
Cleaning Rinse
11) Turn the cleaning valve to the right until completely horizontal (closed). Move the control
switch to the "ICE" position, then replace the front panel. After 3 min., remove the front
panel, then move the control switch to the "OFF" position. Note: The icemaker will not
operate unless the cleaning valve is completely closed.
12) Turn the cleaning valve to the left until completely vertical (open). Move the control
switch to the "WASH" position, then replace the front panel. After 5 min., remove the
front panel, then move the control switch to the "OFF" position.
13) Remove the front insulation panel, then remove the drain plug. After the water tank has
drained, replace the drain plug and front insulation panel.

Bekijk gratis de handleiding van Hoshizaki KMH-2100SRJZ3, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkHoshizaki
ModelKMH-2100SRJZ3
CategorieNiet gecategoriseerd
TaalNederlands
Grootte3252 MB