Hoshizaki F-2001MWJ handleiding
Handleiding
Je bekijkt pagina 7 van 51

7
I. Specications
A. Electrical and Refrigerant Data
The rating label and nameplate provide electrical and refrigerant data. The rating label
can be seen by removing the front panel. The nameplate is located on the rear panel.
For certication marks, see the nameplate.
We reserve the right to make changes in specications and design without prior notice.
1. F-1501M_J(Z)(-C)(-SC)
Single Phase
Model Number F-1501MAJ(-C)(-SC) F-1501MWJ(-C)(-SC) F-1501MRJZ(-C)(-SC)
AC Supply Voltage 208-230/60/1 (3 wire
with neutral)
208-230/60/1 (3 wire
with neutral)
208-230/60/1 (3 wire with neutral)
Compressor 208-230V 9.3RLA
56LRA
208-230V 9.3RLA
56LRA
208-230V 9.3RLA 56LRA
Gear Motor 115V 5.6 FLA 400W 115V 5.6 FLA 400W 115V 5.6 FLA 400W
Fan Motor 115V 1.0 FLA 1/15HP Cabinet:
115V 0.51 FLA 8W
Cabinet: 115V 0.51 FLA 8W
Remote: 115V 3A MAX
Other 115V 0.03A 115V 0.03A 115V 0.03A
Maximum Fuse Size 20 AMPS 20 AMPS 20 AMPS
Max. HACR
Breaker (USA Only)
20 AMPS 20 AMPS 20 AMPS
Max. Circuit Breaker
(Canada Only)
20 AMPS 20 AMPS 20 AMPS
Minimum Circuit
Ampacity
20 AMPS 20 AMPS 20 AMPS
Design Pressure HI-467PSI LO-250PSI HI-427PSI LO-250PSI HI-467PSI LO-250PSI
Refrigerant 404A 2 LB. 5 OZ. 404A 1 LB 4.5 OZ 404A Total Refrigerant Charge with
Hoshizaki Remote Condenser Unit
URC-14FZ: 9 LB. 9 OZ.
Bekijk gratis de handleiding van Hoshizaki F-2001MWJ, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.