Hoshizaki F-2001MWJ handleiding

51 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 19 van 51
19
F. Water Supply and Drain Connections
See Fig. 4, 5, and 6
WARNING
Water supply and drain connections must be installed in accordance with applicable
national, state, and local regulations.
NOTICE
• Normal operating water temperature must be within 45°F to 90°F (7°C to
32°C). Operation of the appliance, for extended periods, outside of this
normal temperature range may affect appliance performance.
Water supply pressure must be a minimum of 10 PSIG and a maximum of 113 PSIG.
If the pressure exceeds 113 PSIG, the use of a pressure reducing valve is required.
• External lters, strainers, or softeners may be required depending on water quality.
Contact your local Hoshizaki Certied Service Representative or local Hoshizaki
distributor for recommendations.
A plumbing permit and services of a licensed plumber may be required in some areas.
The icemaker drain line, dispenser unit/ice storage bin drain line, and water-cooled
condenser drain line (if applicable) must be run separately.
• Drain lines must have 1/4" fall per foot (2 cm per 1 m) on horizontal runs to get a good
ow. A vented tee connection is also required for proper ow.
• Drain lines should not be piped directly to the sewer system. An air gap of a minimum of
2 vertical inches (5-cm) must be between the end of the drain pipes from the icemaker,
dispenser unit/ice storage bin, and water-cooled condenser (if applicable) and the oor
drain.

Bekijk gratis de handleiding van Hoshizaki F-2001MWJ, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkHoshizaki
ModelF-2001MWJ
CategorieNiet gecategoriseerd
TaalNederlands
Grootte4533 MB