3. Sanitizing Solution
Dilute 2.5 . oz. (74 ml or 5 tbs) of a 7.5% sodium hypochlorite solution (chlorine bleach)
with 5 gal. (19 l) of warm water. This is a minimum amount. Make more solution if
necessary. IMPORTANT! For safety and maximum effectiveness, use the solution
immediately after dilution.
4. Sanitizing Procedure - Initial
1) Make sure the power supply is off and the icemaker water supply line shut-off valve
is closed. Remove the front and top panels, then move the power switch to the "OFF"
position.
2) Remove the spout-to-chute strap connecting the spout to the chute assembly, then
remove the spout. Remove the evaporator packing (F-450) or rubber O-ring and nylon
ring (FD-650 and larger) at the top of the cylinder and also remove the spout-to-chute
bracket and spout-to-chute packing between the spout and chute.
3) Pour the sanitizing solution over the extruding head until the evaporator assembly and
the reservoir are full and the solution starts to run through the overow hose on the
reservoir.
4) Remove the backup bin control assembly from the chute assembly, then remove the
chute assembly from the icemaker.
5) Remove the packing at the bottom of the chute. Remove the 3 ties and the chute
insulation (if applicable).
6) Remove the 2 baffles.
7) Remove the plate from the top of the ice chute, then remove the backup bin control
assembly by sliding it slightly towards the chute opening and lifting it off.
8) Disassemble the backup bin control assembly by removing the 2 snap pins, shaft, and
actuator.
9) Soak the spout, evaporator packing (F-450), rubber O-ring and nylon ring (FD-650 and
larger), spout-to-chute packing, spout-to-chute bracket, chute, baffles, plate, and backup
bin control assembly in the sanitizing solution for 10 minutes then wipe them down.
10) Rinse the parts thoroughly with clean water. NOTICE! If the solution is left on these
parts, they will rust.
11) Replace all parts in their correct positions. IMPORTANT! When installing the baffles,
make sure that the bent surface (the one without the studs) faces the actuator so
that the bent surface can guide the ice to the center of the actuator.
12) Move the control switch to the "ICE" position, then move the power switch to the "ON"
position. Replace the panels in their correct positions, then turn on the power supply.
Make ice using the solution until the icemaker stops making ice.
13) Turn off the power supply, then remove the front panel. Move the control switch to the
"DRAIN" position, then replace the front panel in its correct position.
14) Turn on the power supply and allow the water system to drain completely.
15) Turn off the power supply.