B. Electrical and Refrigerant Data
The nameplate provides electrical and refrigerant data. The nameplate is located inside
the storage bin. For certication marks, see the nameplate.
We reserve the right to make changes in specications and design without prior notice.
Model Number C-80BAK
C-80BAK-DS
C-80BAK-AD
C-80BAK-ADDS
AC SUPPLY VOLTAGE ~115/60/1
AMPERES 3.0 AMPS
DESIGN PRESSURE kPa (PSI) HI-3509 (509) LO-1310 (190)
REFRIGERANT g (OZ.) R-290 54 (1.9)
CLIMATE CLASS 5
INSULATION BLOWING GAS HFO 1233 ZD (E)
MINIMUM ROOM FLOOR AREA M² (FT² ) 2.6 (27.8)
HARVEST RATE ≤1,200 LB/DAY (CONTINUOUS)
IP RATING IPX4
Note: Climatic Class 5: This appliance electrical safety tested for operation in maximum
ambient temperature of 104°F (40°C) with 40% relative humidity. However,
normal operating ambient temperature must be within 45°F to 100°F (7°C to
38°C); Normal operating water temperature must be within 45°F to 90°F (7°C to
32°C). Operation of the icemaker, for extended periods, outside of these normal
tempereature ranges may affect icemaker performance.