• Water supply pressure must be a minimum of 10 PSIG and a maximum of 113 PSIG.
Ifthe pressure exceeds 113 PSIG, the use of a pressure reducing valve is required.
• Drain outlet is 1/2" FPT. A minimum of 1/2" nominal ID hard pipe or equivalent is
required for the drain line. Installing a smaller diameter drain line will reduce water ow
and may lead may lead to water leakage or ooding. Be sure there is sufficient extra
drain line for the unit to be pulled out for service.
• Drain line should not be piped directly to the sewer system. An air gap of a minimum of
2vertical inches (5 cm) must be between the end of the drain pipe from the appliance
and the oor drain.
• For gravity drain installation, drain must have 1/4" fall per foot (2 cm per 1 m) on
horizontal runs to get good ow. A vented tee connection is also required for proper
ow. Extend the vent at least 12" (30 cm) above the drain outlet.
• For optional drain pump (HS-5061) installation, refer to the instructions included with
the pump.
Fig. 30
Piping to approved drain.
Leave a 2-inch (5-cm) vertical
air gap between the end of the
pipe and the drain.
2-inch (5-cm)
air gap
Floor
Drain
Shut-Off Valve
Drain Valve
Water Supply Inlet
1/2" FPT
Drain Outlet
1/2" FPT
Vented Tee Connection
Extend the vent at least 12"
(30 cm) above the drain outlet.
Minimum 1/4" Nominal ID Copper Water Tubing or Equivalent
Minimum 1/2" Nominal ID Hard Pipe
or Equivalent
Be sure there is sufficient extra
water supply line and drain line
for the appliance to be pulled
out for service.