30
F. Water Supply and Drain Connections
WARNING
Water supply and drain connections must be installed in accordance with
applicable national, state, and local regulations.
• Connect to potable water supply only. Do not connect to a hot-water supply.
NOTICE
• Normal operating water temperature must be within 45°F to 90°F (7°C to
32°C). Operation of the appliance, for extended periods, outside of this normal
temperature range may affect appliance performance.
Water supply pressure must be a minimum of 10 PSIG (68.9 kPa) and a maximum
of 113PSIG (779.1 kPa). If the pressure exceeds 113 PSIG (779.1 kPa), the use
of a pressure reducing valve is required.
To prevent damage to the appliance, do not operate the appliance when the
water supply is off, or if the pressure is below 10 PSIG (68.9 kPa). Do not run the
appliance until the proper water pressure is reached.
• External lters, strainers, or softeners may be required depending on water quality.
Contact your local Hoshizaki Certied Service Representative or local Hoshizaki
distributor for recommendations.
• In areas where water damage is a concern, install in a contained area with a oor
drain.
Water line installation to the appliance is not warranted by Hoshizaki.
Water-hammer issues must be resolved by a qualied plumber before installing
the appliance. Water hammer can cause appliance damage that may lead to
water leakage or ooding.
A minimum of 1/2" nominal ID hard pipe or equivalent is required for the drain
line. Installing a smaller diameter drain line will reduce water ow and may lead to
water leakage or ooding.
• If using the optional drain pump (HS-5061), test its operation every time the
appliance is cleaned and sanitized. See "III.C. Optional Drain Pump HS-5061" for
details. If the optional drain pump is not operating properly, water could back up
and overow, leading to costly water damage.
Water Supply Inlet Minimum Water Supply Line Size Drain Outlet Minimum Drain Line Size
1/2" Female Pipe
Thread (FPT)
1/4" Nominal ID Copper Water
Tubing or Equivalent
1/2" Female Pipe
Thread (FPT)
1/2" Nominal ID Hard Pipe
or Equivalent
A plumbing permit and services of a licensed plumber may be required in some areas.
A minimum of 1/4" nominal ID copper water tubing or equivalent is required for the
water supply line.
Water supply inlet is 1/2" female pipe thread (FPT).
A water supply line shut-off valve and drain valve must be installed.
• Be sure there is sufficient extra water supply line and drain line for the appliance to be
pulled out for service.