34
Water Tank
Drain
Suction Tube
Tabs
Fig. 31 Fig. 32
Suction Tube
Tabs
B. Startup and Bin Control Check
WARNING
All parts are factory-adjusted. Improper adjustments may adversely affect safety,
performance, component life, and warranty coverage.
To reduce the risk of electric shock, do not touch the power switch, control switch,
or plug (on corded models) with damp hands. If you have to slide the appliance
back for a built-in installation, make sure you do not damage or pinch the water
supply line, drain line, or power cord.
NOTICE
• If the appliance is turned off, wait for at least 3 min. before restarting the appliance
to prevent damage to the compressor.
At startup, conrm that all internal and external connections are free of leaks.
1) Open the water supply line shut-off valve.
2) Make sure the control switch is in the "OFF" position. Plug the unit into the electrical
outlet. WARNING! To reduce the risk of electric shock, do not touch the control
switch or plug with damp hands. If you have to slide the unit back for a built-in
installation, make sure you do not damage or pinch the water supply line, drain
line, or power cord.
3) If required by sanitation code in your area, seal the perimeter where the machine
touches the oor with approved caulk compound in a smooth and easily cleanable
manner.
4) If installing optional drain pump HS-5061, continue to "III.C. Optional Drain Pump
HS-5061." If not, continue to step 5.
5) Move the control switch to the "ICE" position to start the automatic icemaking process.
Allow the appliance to operate for 2 minutes. This allows time for the water tank to ll.
6) Move the control switch to the "OFF" position.
7) Inside the ice storage bin, disconnect the suction tube by squeezing the tabs and
pulling the tube clear. See Fig. 31. Allow the water tank to drain.
8) Reconnect the suction tube as illustrated. See Fig. 32. Make sure the tabs lock into
place; a loose tting may cause a water leak.
9) Clean the ice storage bin liner, door liner, and door gasket using a neutral cleaner.
Rinse thoroughly after cleaning.