Hoshizaki AM-50BAK-AD handleiding

46 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 29 van 46
29
E. Electrical Connection
WARNING
• Electrical connection must meet national, state, and local electrical code
requirements. Failure to meet these code requirements could result in death,
electric shock, serious injury, re, or severe damage to equipment.
This appliance requires an independent power supply of proper capacity.
See the nameplate for electrical specications. Failure to use an independent
power supply of proper capacity can result in a tripped breaker, blown fuse,
damage to existing wiring, or component failure. This could lead to heat
generation or re.
THE APPLIANCE MUST BE GROUNDED: This appliance is equipped with a
NEMA 5-15 three-prong grounding plug to reduce the risk of potential shock
hazards. It must be plugged into a properly grounded, independent 3-prong wall
outlet. If the outlet is a 2-prong outlet, it is your personal responsibility to have
a qualied electrician replace it with a properly grounded, independent 3-prong
wall outlet. Do not remove the ground prong from the power cord and do not use
an adapter plug. Failure to follow these instructions may result in death, electric
shock, or re.
• Do not use an extension cord.
To reduce the risk of electric shock, make sure the control switch is in the "OFF"
position before plugging in or unplugging the appliance.
To reduce the risk of electric shock, do not touch the control switch or plug with
damp hands.
• Do not use an appliance with a damaged power cord. The power cord should not
be altered, jerked, bundled, weighed down, pinched, or tangled. Such actions
could result in electric shock or re. To unplug the appliance, be sure to pull the
plug, not the cord, and do not jerk the cord.
• If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent, or similarly qualied persons in order to avoid a hazard. Upon
replacement, the GREEN ground wire in the power cord must be connected to
the designated grounding screw.
• Usually an electrical permit and services of a licensed electrician are required.
The maximum allowable voltage variation is ±10 percent of the nameplate rating.
• For optional drain pump (HS-5061) installation, refer to the instructions included with
the pump.