Operation Guide
Step 2 – Connecting the Syringes
Attach a syringe to the top nozzle on each side of the fuel cell (these will be for gas storage).
Step 3 – Electrolysis
Connect the red & black lead cables to the fuel cell. During this process make sure the
battery pack is turned o! Attach the red and black cables from the battery pack to the
crocodile clips that are connected to the fuel cell (make sure the red and black leads do
not touch eachother – this would create a short circuit!).
Connect the red lead to the Oxygen (red) side and the black lead to the Hydrogen
(black) side. Once these proper connections are made, turn on the battery pack and
DIY Fuel Cell Kit/Classroom Pack