Installer Setup Options (ISU)
ISU ISU Name ISU Options (factory default in bold)
1050 Temperature Indication Scale
F = Fahrenheit
C = Celsius
(Default varies by model)
2000 Heating System Type
1 = Conventional Forced Air Heat
2 = Heat Pump
3 = Radiant Heat (Boiler)
5 = None (Cool Only)
If you are unsure what type of system you have, refer to your heating/cooling system equipment literature or call an
HVAC professional. If you select the wrong system type, the thermostat will not operate the equipment as intended.
2010 Heating Equipment Type
Conventional Forced Air Heat:
1 = Standard Efficiency Gas
Forced Air
2 = High Efficiency Gas Forced
Air
3 = Oil Forced Air
4 = Electric Forced Air
5 = Hot Water Fan Coil
ISU 2010 not shown when
2000 = Heat Pump
Radiant Heat:
9 = Hot Water Radiant Heat
12 = Steam
2060 Reversing Valve O/B
0 = O (O/B on Cool. O wire is
connected to the O/B terminal
and controls cooling.)
1=B (O/B on Heat. B wire is
connected to the O/B terminal
and controls heat.)
The literature that came with
your heat pump equipment
should indicate whether the
reversing valve is energized in
Heat or Cool mode.
2070 Cool Stages/Compressor Stages 0, 1
2071 Heat Stages Heat Stages: 1
3000 System Changeover
0 = Hidden (Manual only) 1 = Enabled
(Automatic available. In auto mode, the thermostat automatically
switches between heating and cooling to maintain the desired
indoor temperature. This option is not recommended if the outdoor
temperature often stays below 50
°F [10°C] during winter months.)
4103 Minimum Heat Setpoint
32°F to 50°F Default 40°F
0°C to 10°C Default 4.5 °C
Do not set this lower than
40°F/4.5°C unless installed in
a location where pipes are not at
risk of freezing.
7110
Air Filter Replacement Reminder
(Run Time only counts the
time that Heat, Cool or Fan are
running)
0 = Off
1 = 10 Run Time Days
2 = 20 Run Time Days
3 = 30 Run Time Days
4 = 45 Run Time Days
5 = 60 Run Time Days
6 = 90 Run Time Days
7 = 120 Run Time Days
8 = 150 Run Time Days
9 = 30 Calendar Days
10 =45 Calendar Days
11 =60 Calendar Days
12 =75 Calendar Days
13 =3 Calendar Months
14 =4 Calendar Months
15 =5 Calendar Months
16 =6 Calendar Months
17 =9 Calendar Months
18 =12 Calendar Months
19 =15 Calendar Months
14005 Idle screen selection
0 - Minimum Information shown
2 - Maximum display information shown
Depending on system settings, not all options may be available