High iron levels in the water supply can cause staining and may require
an iron lter. High chloride levels in the water supply can cause pitting and may
require a chloride removal system. Contact your local water treatment professional
for proper water treatment.
Sedimentmayrequireaparticulatelter.Dissolvedsolidsmayrequirewatertreatment
such as a water softener, reverse osmosis system, etc. Contact your local water treatment
professional for proper water treatment.
If an inspection of the dishwasher or booster heater reveals lime build-up after the equipment
has been in service, water treatment is recommended. If a water softener is already in
place,ensurethereisasufcientlevelofsalt.ContactyourlocalHobartServiceofcefor
specicrecommendations.
Water Supply Connection
The plumber connecting this machine is responsible for making certain that water lines are
THOROUGHLYFLUSHEDOUTBEFOREconnectingtothedishwasher.This"ush-out"
is necessary to remove all foreign matter, such as chips (resulting from cutting or threading
ofpipes),pipejointcompoundfromthelines;or,ifsolderedttingsareused,bitsofsolder
or cuttings from the tubing. Debris, if not removed, may lodge in the dishwasher's plumbing
components and render them inoperative. Manual valves or solenoid valves fouled by foreign
matter and any expenses resulting from this are NOT the responsibility of the manufacturer
and associated repair costs are not covered under warranty.
Water supply requirements are as follows:
PW10n-ADV, PW10n-ADVSW, PW20n-ADV, PW12-ADV and PW12n-ADVSW models
require both a cold water supply connection and a hot water supply connection.
On PW10n-ADV, PW10n-ADVSW, PW20n-ADV, PW12n-ADV and
PW12n-ADVSW installations, the cold water supply must not exceed 90°F
(32°C) for proper operation. Optimal results are obtained when cold water
supply temperature is below 65°F (18°C). For best results, it may be necessary
to use ½” pipe for cold water pipe size and minimize the distance between
the dishwasher and the entrance into the building. Pipe insulation will also
improve results.
If cold water supply temperature is consistently above 90°F (32°C) or if excessive water
vapor or steam is entering the room after the condensing cycle is complete, contact Hobart
Service to increase condensing time.
Model
Sanitizing
Mode
Connection
Water Supply Temperature
Minimum Maximum Recommended
PW10n-BAS
PW20n-BAS
Hot Water
Sanitizing
Hot Water 110°F (43°C) N/A 140°F (60°C)
PW10n-ADV
PW10n-ADVSW
PW20n-ADV
PW12n-ADV
PW12n-ADVSW
Hot Water
Sanitizing
Hot Water 110°F (43°C) N/A 140°F (60°C)
Cold Water 55°F (13°C) 90°F (32°C) 65°F (18°C)
WATER SUPPLY REQUIREMENTS