Hobart PW12n-ADV handleiding
Handleiding
Je bekijkt pagina 6 van 116

– 6 –
2. Disconnecttheredllhosefromthellsolenoidvalveandallowthewatertodrain.
Reinstall the hose after all the water has drained.
3. Remove the upper wash and rinse arms.
4. Removethebafe(locatedunderthewashandrinsearmsatthetopofthechamber).
a. Removethenutandwasherfromthestudlocatedontheoppositesideofthebafe
from the holding bracket (1, Fig. 4).
b. Slidethebafetothesidetofreethebafefromtheholdingbracket(2,Fig.4).
c. Remove the (4) bolts, lock washers and washers (3, Fig. 4) that secure the energy
recovery assembly from inside the wash chamber.
NOTE: When reinstalling the bolts, ensure there is sufcient permagum on the bolt
threads. Reapply permagum as required.
Fig. 2
Fig. 3
DISCONNECT FILL HOSE TO
DRAIN WATER FROM COIL
UPPER RINSE ARMS
UPPER WASH ARMS