Hobart PW12n-ADV handleiding

116 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 18 van 116
– 18 –
Rinse Aid Feeder (By Others)
The maximum rating for a rinse aid dispenser connected to RPS1 and RPS2 is
1.5 amps at line voltage.
Ifarinseagentfeeder(byothers)isbeinginstalled,removethe¼”compressiontting
located on the side of the air trap located on the back side of the booster tank (Fig. 16)
to install the rinse aid tube. NOTE: For all PW10n and PW12n models, the booster tank
is located on the right side of the machine. For all PW20n models, the booster tank is
located on the left side of the machine.
Delime Feeder (PW10n-ADV / PW10n-ADVSW /PW20n-ADV / PW12n-ADV / PW12n-ADVSW)
An automatic delime feeder with tubing and standpipe is provided to automatically dispense
the delime chemical when needed.
PW10n-ADVSW / PW12n-ADVSW External Chemical Dispenser Connection for
Chemical Lockout
All PW10n-ADVSW and PW12n-ADVSW models are provided with an electrical connection
point to provide a chemical lockout for an external chemical dispenser. For the lockout signal,
the rating of the alarm output from the chemical dispenser must be 24VDC. Connect the
(+) alarm output of the chemical dispenser to TB5-ALM+ located in the PWn controls and
connect the (-) alarm output of the chemical dispenser to TB5-ALM–.
NOTE: The interconnecting power and signal wires/cable from the external chemical dispenser
to the PWn controls are to be provided and installed by others.
RINSE AID
CONNECTION
Fig. 16