– 33 –
Error
No.
Text On Screen Error Description Troubleshooting
018 Wash Tank Water Level
is Too High. Machine
Draining.
Wash tank water level is
above the upper limit.
Press and hold the manual drain button for
5 seconds to drain the unit back to normal
level. Press the ENTER button if displayed
to clear the error. If the ENTER button does
not display, press and hold the power button
for 5 seconds. Machine will drain and power
off. If the error persists, contact Hobart
Service.
020 Rinse System Error. Check
and Clean Rinse Arms.
The wash tank water level
did not increase by the
anticipated amount after
beinglledbytherinse
cycle.
Press the ENTER button to clear the error.
The machine will drain and clear the error.
Ensure tank is clean. If the error persists,
contact Hobart Service.
021 Drain Hose is Clogged.
Clean Drain Hose and
Drain Machine Again.
Signicantwaterremainsin
wash tank after drain cycle.
Ensure power to machine is off and wash
water has cooled. Verify standpipe and
bottom of wash tank are free of debris.
Clean the drain hose and drain the machine.
Ensure drain hose is not kinked and installed
properly. If error remains on screen, press
and hold the power button for 5 seconds to
clear the error. Machine will drain and power
down.
022 Drain System Error. During wash cycle, water
level not maintained at
normal level.
Ensure power to machine is off and wash
water has cooled. Verify standpipe and
bottom of wash tank are free of debris.
Clean the drain hose and drain the ma-
chine. Ensure drain hose is not kinked and
installed properly. If error remains on screen,
press the ENTER button to clear the error.
023 Rapid Fill System Timeout.
Inspect Incoming Water
Line.
Thellvalvehasbeen
active for more than the
maximumallowedlltime,
and the wash tank water
level has not been reached.
This error will only occur if
unit is equipped with rapid
ll.
Ensure incoming water supply is turned on
andthatllhoseisnotkinked.Verifywater
pressure is 15 - 65 psi. Press the ENTER
button to clear the error. If the error persists,
contact Hobart Service.
029 Program Interrupted. Close
Door.
Door is opened during ma-
chine operation.
Close the door and ensure door is fully
seated. The current operation resumes. If
the error persists, contact Hobart Service.
032 Fill Error, Inspect Incoming
Water Line.
The booster water level did
not reach the proper level
within the set amount of
time.
Ensure incoming water supply is turned on
andthatllhoseisnotkinked.Verifywater
pressure is 15 - 65 psi. Press the ENTER
button to clear the error. If the error persists,
contact Hobart Service.
033 Booster Fill Error, Check
Incoming Water Line.
Thellvalvehasbeen
active for more than the
maximumallowedlltime.
Ensure incoming water supply is turned on
andthatllhoseisnotkinked.Verifywater
pressure is 15 - 65 psi. Press the ENTER
button to clear the error. If the error persists,
turn water supply off and contact Hobart
Service.

Bekijk gratis de handleiding van Hobart PW10N-ADV, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.