If sanitizer supply is empty after 3 cycles, "Sanitizer is empty. Rell sanitizer. Machine is
locked." will be displayed along with error code "Error 079" and the machine is inoperable.
Replace sanitizer supply; sanitizer pump will prime automatically during the next cycle.
If detergent supply is empty, “Detergent is low. Rell detergent.” will display along with error
code “Error 074”, but the machine will remain operable. Replace detergent supply; detergent
pump will prime automatically during the next cycle.
For AM16SVLT models only – Wash will not start if the wash tank temperature is below
150°F (66°C). During this time, HEATING is shown on the display and the door will remain
locked. If the machine fails to heat up, “Error 090” will be displayed and the machine will
power down except for the display. After the wash cycle, if the booster temperature is below
181°F (83°C), the wash cycle will be extended up to 8 minutes before completing the rinse
cycle. If the nal rinse temperature does not reach 181°F (83°C), “Minimum nal rinse
temperature not reached. Machine locked” will be displayed along with “Error 084” and the
machine will remained locked until it is drained and relled.
If the detergent supply is empty after 3 consecutive cycles, “Detergent is empty. Rell
detergent. Machine is locked.” will be displayed along with error code “Error 077” and the
machine is inoperable. Replenish the detergent supply, prime, then turn the machine off
and back on again.