T1= Motor key OFF (stand by) – excludes the electronics
reset wash/replace filters signals.
MOTOR OFF
Press briefly to switch the motor off.
RESET FILTERS SIGNALS
In functioning mode, after carrying out filter maintenance,
press the key until hearing the sound signal. The flashing
LED T2 (grease filter) or T3 (carbon filter) stops flashing.
EXCLUDING THE ELECTRONICS
Press the key for 3 seconds. The hood command electron-
ics will be excluded. This function can be useful during the
product cleaning operations. Just repeat the operation to
reinsert the electronics.
T2= Low-speed selection key (suction power) – when flash-
ing it indicates the need to wash the fats filter.
T3= Medium-speed selection key (suction power) - when
flashing it indicates the need to wash or replace the carbon
filter. This signal is normally deactivated. To activate the
alarm, disable the electronic by pressing the T1 button for 3
seconds. Next, simultaneously press buttons T2 and T3 for
3 seconds; at first, only button T2 will flash, then both but-
tons T2 and T3 will flash to indicate activation. Repeat the
procedure to deactivate the alarm; at first buttons T2 and
T3 will flash and subsequently only button T2 to indicate
deactivation.
T4= High-speed selection key (suction power).
T5= Intensive speed selection key (suction power) - dura-
tion 5 minutes: the hood sets this power and at the end of
the 5 minutes returns to the previous setting.
T6= Light key ON/OFF
If the hood fails to operate correctly, briefly disconnect it
from the mains power supply for almost 5 sec. by pulling
out the plug. Then plug it in again and try once more before
contacting the Technical Assistance Service.
MAINTENANCE WARNINGS
Cleaning: For cleaning, simply use a cloth moistened
with neutral liquid detergents. Do not use cleaning tools or
instruments.
• Avoid the use of abrasive products. DO NOT USE ALCO-
HOL!
For product maintenance, see the images at the end
of the installation marked by this symbol.
Anti-Grease Filter: The metallic anti-grease filter
must be cleaned once a month with non-aggressive deter-
gents, manually or in a dishwasher on a short wash at low
temperatures. To remove the anti-grease filter, pull the
spring release handle.
The Anti-Grease Filter traps the grease particles pro-
duced during cooking. When cleaned in the dishwasher,
the metal grease filter may discolour, but its filtering char-
acteristics remain unchanged.
Carbon filter (for filter version only): The cart-
ridge must be replaced at least every four months. It CAN-
NOT be washed or regenerated. As indicated in the draw-
ings section: remove the anti-grease filters, apply a carbon
filter on each side and attach it to the product. Put the anti-
grease filters back in place.
The carbon filter retains any unpleasant odours produced
during cooking. • The saturation of the carbon filter can oc-
cur after somewhat prolonged use depending on the type
of cooking and how regularly the grease filter is cleaned.
Illumination
The lighting system is based on LED technology. LEDs
provide optimal illumination, last up to 10 times longer than
conventional lamps and save 90% of electricity.
Lighting system : The lighting system cannot be re-
placed by the user, contact Customer Service in case of
malfunction.
7

Bekijk gratis de handleiding van Hisense WHI941H8B, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkHisense
ModelWHI941H8B
CategorieAfzuigkap
TaalNederlands
Grootte10410 MB