Installing your new appliance
Ventilation of appliance
Before using the appliance for the first
time, you should be informed of the
following tips.
In order to improve ef
ficiency
of the cooling system and save
energy, it is necessary to maintain
good ventilation around the appliance
for the dissipation of heat. For this
reason, sufficient clear space should
be available around the refrigerator.
Suggest :It is advisable for there to be
at least 50-70mm of space from the
back
to the wall, at least 300mm from its
top,at least 200mm from its side to the
wall and a clear space in front to allow
the doors to open 135°.As shown in
following diagrams
200
300
50-70
8
Climate class
Ambient temperature
SN
N
ST
T
+10°C to +32°C
+16°C to +32°C
+16°C to +38°C
+16°C to +43°C
Note:
the climate class showed in the table
below.
This appliance performs well within
It may not work properly if being
left at a temperature above or below
the indicated range for a long period.
790mm
6
0
0
m
m
7
0
9
m
m
1384mm
135
°
13
5
°
Leveling of appliance
For sufficient leveling and air
circulating in the lower rear section of
the appliance, the bottom feet may
need to be adjusted.
To allow the doors to self-close, tilt
the top backwards by about 10mm.
Stand your appliance in a dry place to
avoid high moisture.
Keep the appliance out of direct
sunlight rain or frost. Stand the
appliance away from heat sources
such as stoves, fires or heaters.
10mm
You can adjust them manually by
hand or by using a suitable spanner.