Hisense HV16CUK handleiding

36 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 23 van 36
7. Plug the machine in again.
Drainage pump
stop
NOTE!
Do not forget to refit the drainage pump stop.
Unblocking the inlet hose filter
If the water supply contains small particles, the outer filter on the inlet hose may become blocked,
which results in the Water inlet fault error message.
1. Turn off the machine using and remove the plug from the wall socket.
2. Turn off the water tap.
3. Unscrew the inlet hose.
4. Carefully remove the outer filter from the inlet hose and clean it.
5. Refit the filter and check that the gasket is correctly positioned.
6. Screw the inlet hose firmly into place.
7. Plug the machine into the wall socket and turn on the water tap. Allow the pressure to settle for
a while and check that the connection is watertight.
Outer filter on
inlet hose
Gasket
Winter storage/transport
Store the dishwasher above freezing temperature and avoid long transport distances in very cold
weather. Transport the dishwasher upright or laying on its back.
Before transporting a used dishwasher, or before prolonged storage, water must first be removed
from the machine.