Hisense 100DM66E handleiding

43 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 30 van 43
23
Serial Port State
:
When the serial port is open, the machine can receive serial
port commands sent by the external controller. See the table below for the specic
command protocol.
Data Parameters
DM-SERIES
Baud Rate 9600
Data length (bits) 8
Parity None
Stop bit 1
Flow control None
Command Format
PC -> TV:
Header
(2 Bytes)
Length
(2 Bytes)
Command
(4 Bytes)
Monitor ID
(1 Byte)
Data
(N Bytes)
Checksum
(1 Bytes)
End
(2 Bytes)
DD FF BB CC
TV -> PC:
Header
(2 Bytes)
Length
(2 Bytes)
Command
(4 Bytes)
Monitor ID
(1 Byte)
Data
(N Bytes)
Checksum
(1 Bytes)
End
(2 Bytes)
AB AB CD CD
[Note]
·
Length is the number of bytes of Command, Data and Checksum.
·
Checksum is XOR of Length, Command, Monitor ID and Data.
RS232