Assembly DCD-3.0
If required the closing caps (E) should be removed before
assembly (removal is not possible after assembly of the
DCD!)
Hold the unit tight with the right hand on the holding grip (F) at
the back and with the left hand on the tightening knob (G).
The tightening lever (G) is then fitted at 90° to the unit. The
system has now been loosened and can be roughly adjusted
in the door. The side with the tightening lever points
towards the black are during this procedure.
The unit is fixed tightly into the door by tightening the
tightening knob (G).
The PVC sheets (H) supplied with the unit are now attached
in line with the door width to the DCD. The first PVC-sheet H
is now being fixed to the adhesive and pushed behind the
fastening clamps (J), then clamped tight using the knurled
screw (K). After this clamp the second sheet overlapping
roughly 20 cm, also behind the fastening clamps (J).
If necessary, both sheets (Length, 2 m) can be shortened with
a cutter.
Now depending on the use (see Section 5) one or two
hoses (Ø 203 mm) can be drawn through the openings of the
DCD.