1. Crossover frequency control (FREQ)
These controls allow you to set the crossover
frequency of the high- or lowpass lter of each
channel pair (A/B or C/D) between 45 and
400 Hz. These controls are activated when
the respective X-Over switch is set to “LPF” or
“HPF” (page 17, point 6).
2. Status LED
The Status LED indicates the operating mode
of the amplier.
Green: The amplier is ready for operation.
Red: Protection Mode active. A malfunction
has occurred that may have di󰀨erent root
causes. The amplier is equipped with protec-
tion circuits against over- and undervoltage
as well as overheating. Please check for con-
necting failures such as short-circuits or other
incorrect connections. If the amplier is over-
heated, the internal temperature protection
will turn o󰀨 the signal output until it reaches a
safe temperature level again. If the amplier
does not turn on, it is defective and needs to
be sent to your local authorized HELIX dealer
for repair service.