8
Max power
Voltage
Picture
ILCOS D code
Self-ballasted LED
modules
1.5 W
220V-240V~
Square/Diameter: 33.2mm x
120mm
DBS-1.5-H-33.2/120
8. TROUBLESHOOTING
Fault
Cause
Solution
Light on, but the motor does not
work
The blades are blocked.
Check the blade.
The capacitor is damaged.
Replace capacitor.
The motor is damaged.
Replace motor.
The internal wiring of motor is cut
off/ disconnected. An unpleasant
smell may be produced.
Replace motor
Both light and motor do not work
Apart from the above mentioned, check the following:
Light damaged.
Replace lights.
Power cord loose.
Connect the wires as per the electric
diagram.
Oil leakage
Outlet and the air ventilation
entrance are not tightly sealed.
Take down the outlet and seal with
glue.
Vibration
The blade, if damaged, can cause
vibrating.
Replace the blade.
The motor is not tightly fastened.
Fasten the motor tightly.
The cooker hood is not tightly
fixed.
Fixed the cooker hood tightly.
Insufficient suction
The distance between the cooker
hood and the cooker top is too
large.
Readjust the distance.
Too much ventilation from open
doors or windows.
Choose a new place to install the
appliance or close some doors /
windows.
The machine inclines
The fixing screws are not tight
enough.
Tighten the fixing screw and make it
horizontal.
The hanging screws are not tight
enough
Tighten the hanging screw and make it
horizontal.