Handleiding
Je bekijkt pagina 8 van 81

www.heinner.com
7
Room ventilation
Oxygen required for combustion is taken from the room air and gases produced are returned directly to the
room.
Good room ventilation is essential for the safe operation of your product.
If there are no windows or doors to be used for room ventilation, additional ventilation should be installed.
However, if the room has a door that opens directly to the outside, there is no need for additional ventilation
systems.
Room size
Ventilation opening
Less than 5 m³
min. 100 cm²
5 m³ to 10 m³
min. 50 cm²
Greater than 10 m³
is not necessary
In basement or cellar
min. 65 cm²
Conversion from natural gas to LPG or from LPG to natural gas
WARNING: Disconnect the product from gas and electricity.
RISK OF BURNS: If the product is hot, wait for it to cool down.
To replace the injector
1. Lift the grate, burner cover and burner of the product so that the injector is visible (See figure 1).
2. With the help of a screwdriver (7 mm) with the tip as shown in figure 2, remove the injector by turning it
(See figure 3).
3. Replace the injectors with suitable ones according to the values in the injector table and the type of gas to
be used in the appliance.
WARNING: Injector replacement should be done by an authorized service.
Flame output speed setting
After replacing the injectors, it is also necessary to adjust the gas taps to the new type of gas.
Before starting the operation, make sure that the appliance plug is plugged in, the gas supply is on and the
burners are completely placed.
Note: Gas setting screw for the low flame position must be loosened when switching from LPG to natural
gas. During switching from natural gas to LPG, it should be tightened.
1. Put the cooker burners in a low position and pull out the cooker control knobs on the control panel (See
figure 4).
Bekijk gratis de handleiding van Heinner HFSC-S66FDC-BIX, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Heinner |
Model | HFSC-S66FDC-BIX |
Categorie | Fornuis |
Taal | Nederlands |
Grootte | 17897 MB |