Technical specifications
WARNING: Technical specification and injector table should be taken into consideration in the change to be
made by the authorized service. Manufacturers may not be held responsible for any problems rising because
of any faulty modification.
WARNING: In order to increase the product quality, the technical specifications may be changed without
prior notice.
WARNING: The values provided with the appliance, or its accompanying documents are laboratory readings
in accordance with the respective standards. These values may differ depending on the use and ambient
conditions.
Injector table
By gas type
burner
specifications
G20,20 mbar
G30,28-30 mbar
Natural gas
LPG
Large burner
Injector
1,15
mm
Injector
0,85
mm
Gas flow
0,271
m³/h
Gas flow
168
g/h
Power
2,90
kW
Power
2,90
kW
Medium burner
Injector
0,97
mm
Injector
0,65
mm
Gas flow
0,159
m³/h
Gas flow
98
g/h
Power
1,70
kW
Power
1,70
kW
Small burner
Injector
0,72
mm
Injector
0,50
mm
Gas flow
0,096
m³/h
Gas flow
55
g/h
Power
0,95
kW
Power
0,95
kW
Note: The diameter values written on the injector are indicated without commas. For example; the diameter,
which is 1,70 mm, is indicated on the injector as 170.
6. INSTALLATION
Check if the electrical and gas installation is proper to bring the appliance in operating condition. If electricity
and gas installation is not suitable, call a certified plumber to arrange the utilities as necessary.
WARNING: Manufacturer shall not be held responsible for damages caused by operations performed by
unauthorized persons.
WARNING: It is customer's responsibility to prepare the location the product shall be placed on and also to
have the electrical installation prepared.
WARNING: The rules specified in the local standards related to electricity and gas should be followed when
installing the product.
WARNING: Check for any damage on the appliance before installing it. Do not have the product installed if it
is damaged. Damaged products cause a risk for your safety.
WARNING: Keep the ventilation channels open.
WARNING: Correct personal protection equipment should be worn and applicable safety regulations should
be followed during installation.
WARNING: The product should be positioned to avoid any air flow that could impact ignition and to prevent
the accumulation of unburned gas.
WARNING: Appliances working with LPG should not be mounted under the floor level.